Sun Microsystems 816-0830-12 Switch User Manual


 
Chapter 8 Configuring the SAN 105
Only the devices on a Fabric-connected host port can be unconfigured through the
cfgadm unconfigure command.
In this example, the c0::50020f2300006077 and c2::50020f2300006107 attachment point
IDs represent different port WWNs for the same device associated with a Sun
StorEdge Traffic Manager device.
3. Unconfigure the Fabric device associated with the Sun StorEdge Traffic Manager
device.
Note Stop all device activity to each Fabric device on the selected port and
unmount any filesystems on each Fabric device. If the device is under any volume
manager’s control, see the documentation for your volume manager for maintaining
the Fabric device.
4. Verify that the selected devices are unconfigured.
# cfgadm -al
Ap_Id Type Receptacle Occupant Condition
c0 fc-fabric connected configured unknown
c0::50020f2300006077 disk connected configured unknown
c0::50020f23000063a9 disk connected configured unknown
c1 fc-private connected configured unknown
c1::220203708b69c32b disk connected configured unknown
c1::220203708ba7d832 disk connected configured unknown
c1::220203708b8d45f2 disk connected configured unknown
c1::220203708b9b20b2 disk connected configured unknown
c2 fc-fabric connected configured unknown
c2::50020f2300005f24 disk connected configured unknown
c2::50020f2300006107 disk connected configured unknown
# cfgadm -c unconfigure c0::50020f2300006077 c2::50020f2300006107