Sun Microsystems 816-0830-12 Switch User Manual


 
130 Sun StorEdge Network FC Switch-8 and Switch-16 Installation and Configuration Guide October 2001
CODE EXAMPLE 9-1 PCI Single Fibre Channel Network Adapter Device Path
3. Manually plumb the fp instance.
Use the ifconfig interface plumb command In this example, interface would be
fcip7..
If no error message is displayed, manual plumbing has succeeded. Repeat this step
for the other fp instances identified in Step 2.
Other /etc/path_to_inst Device Path Entries
The above procedure uses a a PCI single fibre channel network adapter device path
entry from the /etc/path_to_inst file.
CODE EXAMPLE 9-2 shows a device path
entry for a CPCI dual fibre channel network adapter.
CODE EXAMPLE 9-3 shows a
device path entry for a PCI dual fibre channel network adapter.
CODE EXAMPLE 9-2 CPCI Dual Fibre Channel Network Adapter Device Path
CODE EXAMPLE 9-3 PCI Dual Fibre Channel Network Adapter Device Path
“/pci@b,2000/SUNW,qlc@2/fp@0,0” 7 “fp”
TABLE 9-1 PCI Single Fibre Channel Network Adapter /etc/path_to_inst
Device Path Entry
Entry Item Entry Value
Physical Name
“pci@b,2000/SUNW,qlc@2/fp@0.0”
Instance Number 7
Driver Binding
Name
“fp”
# ifconfig fcip7 plumb
"/ssm@0,0/pci@19,700000/pci@2/SUNW,qlc@4/fp@0,0" 6 "fp"
"/pci@1f,4000/pci@4/SUNW,qlc@5/fp@0,0" 3 "fp"