Sun Microsystems 816-0830-12 Switch User Manual


 
108 Sun StorEdge Network FC Switch-8 and Switch-16 Installation and Configuration Guide October 2001
4. Verify that the selected device is unconfigured.
The Sun StorEdge Traffic Manager devices associated with that attachment point ID
are still available to a Solaris host through the path represented by
c0::50020f2300006077.
CODE EXAMPLE 8-6 shows example output you would see for the Sun StorEdge Traffic
Manager device if you use the luxadm(1M) command after performing this
procedure. Notice that only the path represented by c0::50020f2300006077 is
displayed for Sun StorEdge Traffic Manager devices
/dev/rdsk/c6t60020F20000061073AC8B52D000B74A3d0s2
and
/dev/rdsk/c6t60020F20000061073AC8B4C50004ED3Ad0s2.
# cfgadm -al
Ap_Id Type Receptacle Occupant Condition
c0 fc-fabric connected configured unknown
c0::50020f2300006077 disk connected configured unknown
c0::50020f23000063a9 disk connected configured unknown
c1 fc-private connected configured unknown
c1::220203708b69c32b disk connected configured unknown
c1::220203708ba7d832 disk connected configured unknown
c1::220203708b8d45f2 disk connected configured unknown
c1::220203708b9b20b2 disk connected configured unknown
c2 fc-fabric connected configured unknown
c2::50020f2300005f24 disk connected configured unknown
c2::50020f2300006107 disk connected unconfigured unknown
CODE EXAMPLE 8-6
# luxadm display 50020f2300006077
DEVICE PROPERTIES for disk: 50020f2300006077
Status(Port A): O.K.
Vendor: SUN
Product ID: T300
WWN(Node): 50020f2000006077
WWN(Port A): 50020f2300006077
Revision: 0117
Serial Num: Unsupported
Unformatted capacity: 558448.000 MBytes
Write Cache: Enabled
Read Cache: Enabled
Minimum prefetch: 0x0