4-14 Sun Blade T6320 Server Module Service Manual • June 2009
FIGURE 4-8 Removing DIMMs
5. Grasp the top corners of the faulty DIMM and remove it from the system.
6. Place DIMMs on an antistatic mat.
4.3.2 Replacing the DIMMs
See Section 2.2.1, “FB-DIMM Configuration Guidelines” on page 2-7 for complete
memory configuration and installation rules.
Caution – The DIMM rules must be followed. The server module might not operate
correctly if the DIMM rules are not followed. Always use DIMMs that have been
qualified by Sun.
1. Place the replacement DIMMs on an antistatic mat.
2. Ensure that the connector ejector tabs are in the open position.
3. Line up a replacement DIMM with the connector.
Align the DIMM notch with the key in the connector.
a. Push each DIMM into a connector until the ejector tabs lock the DIMM in
place.
b. Perform the procedures described in Section 4.8, “Finishing Component
Replacement” on page 4-28.