Sun Microsystems T6320 Server User Manual


 
2-42 Sun Blade T6320 Server Module Service Manual June 2009
The Predictive Self-Healing technology covers the following Sun Blade T6320 server
module components:
UltraSPARC
®
T2 multicore processor (CPU)
Memory
I/O bus
The PSH console message provides the following information:
Type
Severity
Description
Automated response
Impact
Suggested action for system administrator
If the Solaris PSH facility has detected a faulty component, type the fmdump
command to identify the fault. Faulty FRUs are identified in fault messages using
the FRU name. For a list of FRU names, see Appendix A.
Note Additional Predictive Self-Healing information is available at:
http://www.sun.com/msg
2.7.1 Identifying Faults With the fmadm faulty and
fmdump Commands
2.7.1.1 Using the fmadm faulty Command
Type the fmadm faulty command to identify a faulty component.
1. Type fmadm faulty.
The output shows the UUID of the related fault and provides information for
clearing the fault.
# fmdadm faulty
STATE RESOURCE /UUID
faulted cpu:///cpuid=8/serial=FAC006AE4515C47
8856153f-6f9b-47c6-909a-b05180f53c07