Sun Microsystems T6320 Server User Manual


 
2-46 Sun Blade T6320 Server Module Service Manual June 2009
1. After replacing a faulty FRU, at the ILOM prompt, type the ILOM -> show
faults command to identify PSH detected faults.
PSH detected faults are distinguished from other faults by the text:
Host detected fault.
For example:
-> show /SP/faultmgmt
If no fault is reported, you do not need to do anything else.
If the fault is reported, continue with Step 2.
2. Type the clear_fault command with the UUID provided in the showfaults
output:
2.8 Collecting Information From Solaris OS
Files and Commands
With the Solaris OS running on the Sun Blade T6320 server module, you have all the
Solaris OS files and commands available for collecting information and for
troubleshooting.
In the event that POST, ILOM, or the Solaris PSH features did not indicate the source
of a fault, check the message buffer and log files for fault notifications. Hard drive
faults are usually captured by the Solaris message files.
Type the syslogd command to view the most recent system message.
Use the /var/adm/messages file to view the system messages log file.
2.8.1 Checking the Message Buffer
1. Log in as superuser.
-> set /SYS/component clear_fault_action=true
Clearing fault from component...
Fault cleared.