Sun Microsystems T6320 Server User Manual


 
Chapter 2 Sun Blade T6320 Server Module Diagnostics 2-5
TABLE 2-1 Diagnostic Flowchart Actions
Action
No. Diagnostic Action Resulting Action
For more information, see
these sections
1.
Check the OK LED. The OK LED is located on the front of the Sun Blade
T6320 server module.
If the LED is not lit, check that the blade is properly
connected and the chassis has power.
Section 2.3, “Interpreting
System LEDs” on page 2-12
2.
Type the ILOM
show
/SP/faultmgmt
command to check
for faults.
The faultmgmt command displays the following
types of faults:
Environmental faults
Solaris Predictive Self-Healing (PSH) detected
faults
POST detected faults
Faulty FRUs are identified in fault messages using
the FRU name. For a list of FRU names, see
TABLE 1-3.
Section 2.5.3, “Displaying
System Faults” on
page 2-21
3.
Check the Solaris
log files for fault
information.
The Solaris message buffer and log files record
system events and provide information about faults.
If system messages indicate a faulty device,
replace the FRU.
To obtain more diagnostic information, go to
Action
4.
Section 2.8, “Collecting
Information From Solaris
OS Files and Commands”
on page 2-47
4.
Run the SunVTS
software.
SunVTS can exercise and diagnose FRUs. To run
SunVTS, the server module must be running the
Solaris OS.
If SunVTS reports a faulty device replace the FRU.
If SunVTS does not report a faulty device, go to
Action
5.
Section 2.10, “Exercising
the System With SunVTS”
on page 2-51
5.
Run POST. POST performs basic tests of the server module
components and reports faulty FRUs.
If POST indicates a faulty FRU, replace the FRU.
If POST does not indicate a faulty FRU, go to
Action
9.
Section 2.6, “Running
POST” on page 2-31
6.
Determine if the
fault is an
environmental
fault.
If the fault listed by the show /SP/faultmgmt
command displays a temperature or voltage fault,
then the fault is an environmental fault.
Environmental faults can be caused by faulty FRUs
(chassis power supply, fan, or blower) or by
environmental conditions such as high ambient
temperature, or blocked airflow.
Section 2.5.3, “Displaying
System Faults” on
page 2-21
See the Modular System
Service Manual, 820-0051.