Sun Microsystems T6320 Server User Manual


 
4-24 Sun Blade T6320 Server Module Service Manual June 2009
4. To display additional configuration information, list the device properties by
using the .properties command.
5. Return to the root node by using the unselect-dev command.
Note At this point, there are no volumes created and the output from a probe-
scsi-all command will not display any drives.
If no errors or issues are discovered, continue to “Creating a Bootable Array With
the RAID 5 Expansion Module” on page 25 to complete the installation process. If
any issues are discovered, correct them and retest the HBA before continuing.
4.6.2 Configuring the RAID 5 Expansion Module
For details, see Appendix B and Appendix C.
{0} ok .properties
firmware-version 15825
assigned-addresses 82e70010 00000000 50000000 00000000 00200000
82e70030 00000000 50200000 00000000 00080000
compatible pciex9005,285.108e.7aac.9
pciex9005,285.108e.7aac
pciex9005,285.9
pciex9005,285
pciexclass,010400
pciexclass,0104
model AAC,285
reg 00e70000 00000000 00000000 00000000 00000000
03e70010 00000000 00000000 00000000 00200000
version 0.00.01
wide 00000010
device_type scsi-2
name scsi
fcode-rom-offset 00011800
interrupts 00000001
cache-line-size 00000010
class-code 00010400
subsystem-id 00007aac
subsystem-vendor-id 0000108e
{0} ok unselect-dev