When Replacing Faulty FB-DIMMs
Within each branch, ensure that the replacement FB-DIMM has the same part
number as the FB-DIMM you are removing. If you are unable to obtain an FB-DIMM
with the same part number, you might need to replace all FB-DIMMs in the branch
to ensure that they all have the same part number.
The following table lists the supported FB-DIMMs and part numbers.
2.2.1.1 DIMM Installation Rules
Caution – The following FB-DIMM rules must be followed. The server module
might not operate correctly if the FB-DIMM rules are not followed. Always use
DIMMs that have been qualified by Sun.
FB-DIMMs must be installed in groups of four, each of the same capacity.
The following configurations are supported in the Sun Blade T6320 server module:
■ Four FB-DIMMs (Group 1) Channel 0, FB-DIMM connector 0 in all branches must
be populated.
■ Eight FB-DIMMs (Groups 1 and 2)
■ Sixteen FB-DIMMs (Groups 1, 2 and 3)
See Section 4.3.1, “Removing the DIMMs” on page 4-10 for FB-DIMM installation
instructions.
FIGURE 2-3 shows where to to install FB-DIMMs in groups of four.
TABLE 2 Supported FB-DIMMs and Part Numbers
Description Ordered Separately Assembled at Factory
FB-DIMMs Supported at November 2007 Release of the Server Module
1 GB single rank x4 FB-DIMM x 2 (2 GB FB-DIMM Memory Kit) X4200A 4200A
2 GB single rank x4 FB-DIMM x 2 (4 GB FB-DIMM Memory Kit) X4203A 4203A
4 GB dual rank x8 DIMM x 2 (8 GB FB-DIMM Memory Kit) X4204A 4204A
FB-DIMMs Added at October 2008 Release of the Server Module
1 GB dual rank x8 FB-DIMM x 2 (2 GB FB-DIMM Memory Kit) X4200AF 4200AF
2 GB dual rank x8 FB-DIMM x 2 (4 GB FB-DIMM Memory Kit) X4203AF 4203AF
8 GB dual rank x8 FB-DIMM x 2 (16 GB FB-DIMM Memory Kit) X4290AF 4290AF