Sun Microsystems T6320 Server User Manual


 
Chapter 2 Sun Blade T6320 Server Module Diagnostics 2-33
TABLE 2-7 shows typical combinations of ILOM variables and associated POST
modes.
2.6.2 Changing POST Parameters
You can use the web interface or the CLI to change the POST parameters.
2.6.2.1 Using the Web Interface to Change POST Parameters
1. From the ILOM web interface, select the Remote Console tab (FIGURE 2-17).
2. Select the Diagnostics Tab.
3. Select the POST settings that you require.
TABLE 2-7 describes how the POST settings will execute.
4. Click the Save button.
Note – If you do not have a console window open, you should open one. POST will
only display output to a console window, not the web interface.
TABLE 2-7 POST Modes and Parameter Settings
Parameter
Normal Diagnostic Mode
(default settings) No POST Execution
Diagnostic Service
Mode
Keyswitch Diagnostic
Preset Values
diag_mode normal off service normal
setkeyswitch
*
* Thesetkeyswitch parameter, when set to diag, overrides all the other POST variables.
normal normal normal diag
diag_level min n/a max max
diag_trigger power-on-reset
error-reset
none all-resets all-resets
diag_verbosity normal n/a max max
Description of POST
execution
This is the default POST
configuration. This
configuration tests the
system thoroughly, and
suppresses some of the
detailed POST output.
POST does not
run, resulting in
quick system
initialization, but
this is not a
suggested
configuration.
POST runs the full
spectrum of tests
with the maximum
output displayed.
POST runs the full
spectrum of tests
with the maximum
output displayed.