Chapter 2 Sun Blade T6320 Server Module Diagnostics 2-21
2.5.2 Changing POST Settings With the ILOM CLI
1. Type the show command to see the current POST settings:
2. Change the POST settings with the set /HOST/diag command.
For example:
2.5.3 Displaying System Faults
ILOM displays the following faults with the web interface and CLI:
■ Environmental faults – Temperature or voltage problems that might be caused by
faulty FRUs (power supplies, fans, or blower), or by room temperature or blocked
air flow.
■ POST detected faults – Detected by the power-on self-test diagnostics.
■ PSH detected faults – Detected by the Solaris Predictive Self-healing (PSH)
technology
-> show /HOST/diag
/HOST/diag
Targets
Properties:
level = max
mode = normal
trigger = power-on-reset error-reset
verbosity = normal
Commands:
cd
set
show
-> set /HOST/diag level=min
Set ’level’ to ’min’
-> set /HOST/diag mode=Normal
Set ’mode’ to ’Normal’
-> set /HOST/diag verbosity=max
Set ’verbosity’ to ’max’
-> set /HOST/diag trigger=power-on-reset trigger=error-reset
Set ’trigger’ to ’power-on-reset’
Set ’trigger’ to ’error-reset’