2.5.2 Changing POST Settings With the ILOM CLI
1. Type the show command to see the current POST settings:
2. Change the POST settings with the set /HOST/diag command.
For example:
2.5.3 Displaying System Faults
ILOM displays the following faults with the web interface and CLI:
Environmental faults – Temperature or voltage problems that might be caused by
faulty FRUs (power supplies, fans, or blower), or by room temperature or blocked
air flow.
POST detected faults Detected by the power-on self-test diagnostics.
PSH detected faults Detected by the Solaris Predictive Self-healing (PSH)
technology
-> show /HOST/diag
/HOST/diag
Targets
Properties:
level = max
mode = normal
trigger = power-on-reset error-reset
verbosity = normal
Commands:
cd
set
show
-> set /HOST/diag level=min
Set ’level’ to ’min’
-> set /HOST/diag mode=Normal
Set ’mode’ to ’Normal’
-> set /HOST/diag verbosity=max
Set ’verbosity’ to ’max’
-> set /HOST/diag trigger=power-on-reset trigger=error-reset
Set ’trigger’ to ’power-on-reset’
Set ’trigger’ to ’error-reset’