Toshiba A100 Webcam User Manual


 
3.22 Log Utilities 3 Tests and Diagnostics
PORTEGE A100 Maintenance Manual (960-460) 3-53
3.22 Log Utilities
3.22.1 Function Description
This function logs error information generated while a test is in progress and stores the results in
RAM. This function can also store data on a floppy disk or output the data to a display or a printer.
If the power switch is turned off, the error information will be lost. The error information is displayed
in the following order:
1. Error count (CNT)
2. Test name, Subtest number (TS-No)
3. Pass count (PASS)
4. Error status code (STS)
5. FDD/HDD or memory address (ADDR)
6. Write data (WD)
7. Read data (RD)
8. HDC status code (HSTS)
9. Error status name (ERROR STATUS NAME)