3Com MSR 30 Network Router User Manual


  Open as PDF
of 2742
 
467
Description Use the x25 timer tx2 command to set the reset request (indication) timer for
DTE (or DCE).
Use the
undo x25 timer tx2 command to restore the default.
By default, the timer on a DTE is 180 seconds, and that on a DCE is 60 seconds.
According to X.25, a timer should be started when a DTE sends a reset request (or
a DCE sends a reset indication). If no peer acknowledgement is received after the
timer timeout, the sending end will take some measures to guarantee the normal
proceeding of the local procedure.
Related command: x25 timer tx0, x25 timer tx1, x25 timer tx3.
Example # Set the reset timer on the X.25 interface Serial1/0 to 120 seconds.
<Sysname> system-view
[Sysname] interface serial 1/0
[Sysname-Serial1/0] x25 timer tx2 120
x25 timer tx3
Syntax x25 timer tx3 seconds
undo x25 timer tx3
View Interface view
Parameter seconds: Time of the clear request (indication) sending timer in seconds, ranging
from 1 to 1000.
Description Use the
x25 timer tx3 command to set the clear request (indication) sending
timer for DTE (or DCE).
Use the
undo x25 timer tx3 command to restore the default.
By default, the clear timer on a DTE is 180 seconds, and that on a DCE is 60
seconds.
According to X.25, a timer should be started when a DTE sends a clear request (or
a DCE sends a clear indication). If no peer acknowledgement is received after the
timer timeout, the sending end will take some measures to guarantee the normal
proceeding of the local procedure.
Related command: x25 timer tx0, x25 timer tx1, x25 timer tx2.
Example # Set the clear timer on the X.25 interface Serial 2/0 to 100 seconds.
<Sysname> system-view
[Sysname] interface serial 2/0
[Sysname-Serial2/0] x25 timer tx3 100