Issue 4 August 2002 5-1
Maintenance
Introduction
This chapter provides procedures for using a variety of maintenance tools to
manage and support your EC500 implementation. Information is also provided on
Display Error/Alarms and System Restarts.
Key maintenance tools are:
■ Display Capacities - the ability to display the number of used and unused
XMOBILE stations, as well as the number of XMOBILE stations assigned
to any particular type (EC500, DECT, or PHS).
■ List XMOBILE by Cell Phone Number - the ability to list EC500 XMOBILE
stations by complete or partial cell phone number(s).
■ Busy out and release - capabilities for managing the in-service and
out-service state of XMOBILE stations.
■ Status Station - fields that shows EC500 enabled or disabled status.
When EC500 XMOBILE stations are active on a call no maintenance testing is
performed, although a hardware connection exists along the ISDN-PRI or H.323
IP port and the trunk media to the cell phone system.
Display Capacities
The administration to display system capacities for XMOBILE stations is
performed on page 8 of the System Capacities screen. EC500-related information
that you can view is:
■ The number of administered XMOBILE stations.
■ The number of unadministered XMOBILE stations.
■ The number of XMOBILE stations assigned to DECT, PHS, or EC500
XMOBILE types.
■ The number of XMOBILE stations.