Christie Digital Systems CSP70 Projector User Manual


 
Section 3: Operation
RPMSP & CSP70-D100U User’s Manual 3-43
.
Signal Type Description (Input Location)
#1 5 BNCs (RGBHV or YPbPr)
#2 DVI - I (analog or digital)
#3 Decoded signals (Input 3, Input 4, Composite video, S-Video, or any video
signal via Input 1 BNC connectors or via an analog option card).
#4 Analog Option Cards
#5 Digital Option Cards
#6 Digital Option Cards
* HD interlaced sources are not recommended for the PIP window.
Other PIP or Seamless Switching tips to keep in mind include:
When using 2 digital signals or 1 analog and 1digital, each must be 165
megapixels.
When using two analog signals, each must be 90 megapixels.
Avoid using an interlaced source in the PIP window
Seamless switching may affect image quality in some cases
NOTE: To control the primary image, access all picture controls through the Main
menu. To control the secondary (PIP) image, access picture controls through the
Picture-in-Picture and Switching menu.
Use the first of six
options in the PIP
and Switching menu
to enable and define
how you want to use
PIP.
Swap Main and PIP Image
Toggle the current picture-in-picture relationship so that the primary (main) image
becomes secondary (PIP), and the secondary image becomes primary. Swapping is
available only when PIP is enabled.
NOTE: There may be a slight delay when swapping the Primary and Secondary
images.
PIP Enable
Short cut: Press
on the
remote.
Toggle to display from two
sources at once (Picture-in-
Picture) or the primary source
only. This checkbox turns the
secondary source on and off.
NOTE: Disable PIP and Best Switching for Interlaced sources > 35kHz.
Workin
g
with PIP '