Cisco Systems 7326 Computer Hardware User Manual


 
5-39
Cisco Wide Area Application Engine 7326 Hardware Installation Guide
OL-6831-02
Chapter 5 Troubleshooting the System Hardware
Symptoms and Solutions
035-253-S99 RAID adapter initialization
failure.
1. ServeRAID adapter in slot s is not
configured properly.
2. Check the cable.
3. Check the SCSI backplane.
4. Check the adapter.
075-XXX-000 Failed power supply test. Check the power supply.
089-XXX-001 Failed microprocessor test.
1. Check VRM 1 for microprocessor 1.
2. Check the microprocessor 1.
089-XXX-002 Failed optional microprocessor
test.
1. Check VRM 2 for optional
microprocessor 2.
2. Check the optional microprocessor 2.
166-198-000
System
Management:
Aborted
Unable to communicate with
ASM
4
. It may be busy. Run the
test again.
1. Run the diagnostic test again.
2. Correct other error conditions, including
other failed system management tests, and
retry.
3. Disconnect all device and option power
cords from the device, wait 30 seconds,
reconnect, and retry.
4. Check the system board.
166-201-001
System
Management:
Failed
I2C bus error(s). See
SERVPROC and DIAGS entries
in event log.
1. Memory DIMMs need to be reseated. Call
your service representative.
2. Check the memory DIMMs.
3. Check the system board.
166-201-002
System
Management:
Failed
I2C bus error(s). See
SERVPROC and DIAGS entries
in event log.
1. I2C cable between the operator information
panel and the system board (J22) might
need to be reseated. Call your service
representative.
2. Check the diagnostic panel.
3. Check the system board.
Table 5-8 Error Code Definitions (continued)
Error Code Problem Action