Epson S5U1C63000A Computer Accessories User Manual


 
CHAPTER 8: DEBUGGER
S5U1C63000A MANUAL EPSON 121
(S1C63 FAMILY ASSEMBLER PACKAGE)
8.3.3 Start-up Messages
When the debugger starts up, it outputs the following message in the [Command] window. (Refer to the
next section for details about windows.)
Debugger63 Ver x.xx Copyright SEIKO EPSON CORP. 1998-2001
Connecting COMx with xxxxx baud rate ... done
Parameter file name : xxxxxxxx.par
Version : xx
Chip name : 63xxx
CPU version : x.x
PRC board version : x.x
LCD board version : x.x
EXT board version : x.x
ICE hardware version : x.x
ICE software version : x.x
DIAG test : omitted
Map............................... done
Initialize........................ done
>
8.3.4 Hardware Check at Start-up
When the debugger is invoked, it first performs the tests and initializing operations described below.
(1) Testing connection of the ICE
Debugger db63 first checks to see that the ICE is connected to your system and that communication is
possible without any problems. The following message is displayed in the [Command] window.
During test
Connecting COMx with xxxxx baud rate ...
When terminated normally
Connecting COMx with xxxxx baud rate ... done
When an error is encountered
Connecting COMx with xxxxx baud rate ... failure
<error message>
The error message indicates that communication between the personal computer and the ICE is not
functioning properly. In this case, to verify the following:
• A standard RS-232C cable is used
• The COM port is correct
• The baud rates on both sides are matched
• The PRC board is correctly fitted in place
• The ICE's power is turned on
• The ICE remains reset