CHAPTER 8: DEBUGGER
192 EPSON S5U1C63000A MANUAL
(S1C63 FAMILY ASSEMBLER PACKAGE)
brc (register break clear)
Function
This command clears the register break conditions that have been set.
Format
>brc↵ (direct input mode)
GUI utility
[Break | Register Break …] menu item
When this menu item is selected, a dialog box appears for clearing the register break conditions. (See
the br command.)