Epson S5U1C63000A Computer Accessories User Manual


 
CHAPTER 8: DEBUGGER
S5U1C63000A MANUAL EPSON 215
(S1C63 FAMILY ASSEMBLER PACKAGE)
>tm
Single delay mode
Trigger Address : 0116
Position: Middle
1.normal 2.single delay 3.address area ...? 3 ... [2. address area] is selected.
Trigger address ? :116 ... Trigger address is input.
1.in area 2.out area ...? 1 ... In/out is selected.
Start address ? 110 ... Address range is input
End address ? 200 in up to 4 locations.
Start address ? ... Terminated by [Enter] key.
>
If you enter the [Enter] key only, the command will be canceled.
However, if more than one pair of addresses is specified after selecting the address-area trace mode
(one pair of addresses is specified in the above example), the range of specified addresses will be set
as the trace area.
Notes
The trigger addresses set here are marked by the letter "T" at the beginning of the address lines
displayed in the [Source] window.
The address you specified must be within the range of the program memory area available with each
microcomputer model.
An error results if the input one is not a hexadecimal number or not a valid symbol.
Error : invalid value (no such symbol / symbol type error)
An error results if the limit is exceeded.
Error : Address out of range, use 0-0xXXXX
GUI utility
[Trace | Trace Mode Set …] menu item
When this menu item is selected, a dialog box appears allowing selection of a trace mode.
Select a trace mode using the radio
button.
Enter addresses and/or select an option
and then clock [OK].
Normal trace mode
Single-delay trace mode
Address-area trace mode