Extron electronic 68-1383-01 REV. E Switch User Manual


 
Command/Response Table for IP Setup SIS Commands (continued)
Command Function
SIS Command
(Host to Unit)
Response
(Unit to Host)
Additional description
IP setup commands (continued)
Set e-mail events for recipient
E
F,
X5!
,
X5$
,
X5#
EM
}
IpeF,
X5!
,
X5$
,
X5#]
You must rst have set an e-mail
recipient for the e-mail account number
X5!
), using the separate Set e-mail
recipient (CR) command.
Example:
E
F,72,0,2EM
}
IpeF*72*0*3
]
E-mail account #72, JSmith, will receive
fail/missing and fixed/restored messages
for both fans.
Read e-mail notifications for one
account (recipient)
EX5!
,
X5$
,
X5#
EM
} X5$
,
X5$
,
X5$
, ... ,
X5$]
Set DHCP on or off
EX5^
DH
}
Idh
X5^]
Read DHCP on/off status
E
DH
} X5^]
Set serial port parameters
EX5&
*
X5*
,
X5(
,
X6)
,
X6!
CP
}
Cpn
X5&
Ccp
X5*
,
X5(
,
X6)
,
X6!]
Read serial port parameters
EX5&
CP
}
X5*
,
X5(
,
X6)
,
X6!]
Configure flow control
EX5&
*
X6$
,
X6%
CF
]
Cpn
X5&
Cfl
X6$
,
X6%]
Read flow control
E
CF
X6$
,
X6%]
Configure receive timeout
EX5&
*
X6^
,
X6&
CE
]
Cpn
X5&
Cce
X6^
,
X6&]
Read receive timeout
E
CE
X6^
,
X6&]
Set mode
EX5&
*
X6@
CY
}
Cpn
X5&
Cty
X6@]
Read mode
EX5&
CY
} X6@]
Set verbose mode
EX6#
CV
}
Vrb
X6#]
Read verbose mode
E
CV
} X6#]
Configure current port timeout
E
0*
X6*
TC
}
Pti0*
X6*]
Read current port timeout
E
0TC
} X6*]
Configure global IP port timeout
E
1*
X6*
TC
}
Pti1*
X6*]
Read global IP port timeout
E
1TC
} X6*]
Clear room preset ties
E
+
X2%
*
X2#
P0*!
]
Rmm
X2%
Spr
X2#]
Clear all ties in room
X2#
preset
X2#
.
Special Characters
The HTML language reserves certain characters for specific functions. The switcher does not
accept these characters as part of preset names, name of the switcher, passwords, or locally
created file names.
The switcher rejects the following characters:
{space (spaces are ok for names)} + ~ , @ = ‘ [ ] { } < > ’ “ semicolon (;) colon (:) |
\ and ?.
MTPX Plus Series • Programming Guide 95