Extron electronic IN1608 Switch User Manual


 
IN1606 and IN1608 Series Scaling Presentation Switcher • Operation 28
User Presets Submenu
Figure 21. User Presets Submenu (IN1608)
The User Presets submenu manages user presets only (input presets are not available
through the OSD menu). User presets save the current picture control settings for the
selected input for recall later or copy settings to other inputs. There are 16 user presets
available per input. Press the Input Selection buttons to select an input.
NOTE: If a saved preset is not named, “User Preset XX” is assigned.
From the Save, Recall, or Clear submenu item, press the navigation buttons to select the
desired preset to either save picture control settings, recall previously saved picture control
settings, or clear a preset of saved settings.
User presets save the following settings:
Brightness and contrast
Color and tint
Detail
Image size and position
Preset name
NOTE: To manage input presets, use SIS commands (see Preset Commands on
page 57) or the internal Web pages (see Preset Management Page on page 112).