Extron electronic IN1608 Switch User Manual


 
IN1606 and IN1608 Series Scaling Presentation Switcher • SIS Configuration and Control 42
Password Information
The ] Password: prompt requires a password (administrator level or user level) followed
by a carriage return. The prompt is repeated if the correct password is not entered. If the
correct password is entered, the unit responds with ] Login Administrator ] or
] Login User ], depending on password entered. If passwords are the same for both
administrator and user, the unit defaults to administrator privileges.
Error Responses
When the scaler receives a valid command, it executes the command and sends a
response to the host device. If the unit is unable to execute the command, it returns an error
response to the host.
Error codes
E01 — Invalid input number E17 — Invalid command for signal type
E10 — Invalid command E22 — Busy
E11 — Invalid preset number E24 — Privilege violation
E12 — Invalid port number E25 — Device not present
E13 — Invalid parameter E26 — Maximum number of connections
exceeded
E14 — Not valid for this configuration E28 — Bad filename or file not found
Error response references
These references in the command and response tables note particular error responses to
that command.
14
= Commands that give an E14 (invalid command for this configuration) error if sent to a
product whose current configuration does not support the command
24
= Commands that give an E24 (privilege violation) error if not administrator level
28
= Commands that may give an E28 (file not found) error