Extron electronic IN1608 Switch User Manual


 
IN1606 and IN1608 Series Scaling Presentation Switcher • Internal Web Pages 91
Image Settings Page
The Image Settings page adjusts signal sampling and picture control settings, saves and
recalls user and input presets, and applies overscan settings. Click the Image Settings
icon (see figure 58,
4
on page 86) on the Global Navigation Bar to open the Image
settings
page.
Figure 63. Image Settings Page
Signal Sampling panel
Signal sampling optimizes the input signal to the scaler for the currently selected input.
Figure 64. Signal Sampling Panel
To manually adjust signal sampling settings, enter a value within the Min and Max values
displayed to the right of each adjustable setting (see figure 64,
1
) or click the Up or Down
arrows. An asterisk beside a chosen value for a signal sampling setting indicates that it is a
default value for the applied video signal (for example, see Active Lines in figure 64).
To automatically adjust these settings, perform one of the following:
Click the Auto-Image button (
2
) to perform a one-time Auto-Image.
Click the Auto-Image & Fill button (
3
) to perform a one-time Auto-Image and fill
the entire video output (ignores aspect ratio setting).
Click the Auto-Image & Follow button (
4
) to perform a one-time Auto-Image and to
maintain the aspect ratio of the input signal (ignores aspect ratio setting).