HP (Hewlett-Packard) 5SI All in One Printer User Manual


 
SIMM Validation Error Messages
Validation error messages appear when a SIMM fails to be initialized
when the mopier is turned on. This error is in the format
53.XY.ZZ ERROR. Table 7-1 lists these errors.
Table 7-1 Validation Error Messages
X (Hardware Type) Y (Hardware Device) ZZ (Error Number)
0: ROM
1: RAM
0: Internal Memory
1: SIMM Slot 1
2: SIMM Slot 2
3: SIMM Slot 3
4: SIMM Slot 4
0: Unsupported memory
1: Unrecognized memory
2: Unsupported memory size
3: Failed RAM test
4: Exceeded maximum RAM size
5: Exceeded maximum ROM size
6: Invalid SIMM speed
7: SIMM reporting information incorrectly
8: SIMM RAM parity error
9: (n/a)
10: SIMM address conflict
11: ROM out of bounds
12: Could not make temporary mapping
Although these errors can be ignored, the SIMM that caused the error
will not be configured. You can still print if the SIMM has more than
one bank of memory.
7
Maintenance &
Troubleshooting
EN Maintenance and Troubleshooting 7-21