AI296 Version 9.8x User’s Guide
Link Configuration: BX.25 Configuration
6-6
Configuration in the AI296 Local Menu System
1. Access the X.25 Link Menu.
2. Select
BX.25 Menu. The BX.25 Menu appears.
3. For
Use BX.25 Configuration Values, select Enabled or Disabled. The default is
Enabled.
This example displays
Use BX.25 Configuration Values set to Enabled.
BX.25 Modulo
Description
This menu item defines a modulo value. A modulo is used by the BX.25 protocol to
define the value at which the packet sequence numbers will rollover.
Menu Item Type
Data
Link Type Availability
X.25
Configuration in the AI198 Menu System
1. Access Menu 4.2.11.12.11.
2. For
04 Modulo, enter 4, and the desired value. The default is 256.
This example displays
04 Modulo set to 200.
BX.25 Menu
Link being configured . . . . . . . . . . . . . . . . . . . . . . . . . 03
BX.25 Support . . . . . . . . . . . . . . . . . . . . [Enabled] Disabled
Use BX.25 Configuration Values. . . . . . . . . . . . [Enabled] Disabled
>4,200
Menu 4.2.11.12.11
01*BX25 Support (Enabled, Disabled)------------------------------------Disabled
02*Use these configuration values (Enabled, Disabled)------------------ Enabled
03 Sending Unit Number (0 - 9)------------------------------------------------0
04 Modulo (5 - 256)---------------------------------------------------------200