Kentrox AI296 Computer Hardware User Manual


 
AI296 Version 9.8x User’s Guide
Link Configuration: General Link Properties Configuration
6-24
This MLT link example displays 09 Auto Disable Error Limit set to 25000.
Configuration in the AI296 Local Menu System
1. Access the Link Menu.
2. Select
Auto Disable Menu. The Link Auto Disable Menu appears.
3. For
Errors/second limit for auto disable, enter the error limit value. The default
is
0.
This example displays
Errors/second limit for auto-disable set to 25000.
Flow Control
Description
This menu item enables a receiving device to tell a sending device to stop sending
data when data is coming too fast and to start sending data when the receiver is
ready.
There are two available flow control options for AI296:
z None—Specifies no flow control.
z XonXoff—Specifies the flow control option that uses standard ASCII control
characters to tell a sending device to stop or resume data transmission.
Menu Item Type
Toggle
Link Type Availability
Async and AsyncPPP
>9,25000
Menu 4.2.11.12
01 Link number (1-16)--------------------------------------------------------01
02*Link Type (Async, X25, HDLC, SyncPPP, AsyncPPP, MLT)---------------- MLT
03 Link Description------------------------------ Async link 1
04*Link state (Enabled, Disabled)-------------------------------------- Enabled
05 Port speed (0 - 128000 bps, 0 is external clocking)-------------------009600
06*Hardware Interface (RS232,RS530,V.35)----------------------------------RS232
07*Sync Port Encoding (NRZ, NRZI)-------------------------------------------NRZ
08+LAPB Parameters
09 Auto Disable Error Limit (0-1000000)---------------------------------0025000
Link Auto Disable Menu
Link being configured . . . . . . . . . . . . . . . . . . . . . . . . . 03
Errors/second limit for auto-disable . . . . . . . . . . . . . . . . . . 25000