Kentrox AI296 Computer Hardware User Manual


 
AI296 Version 9.8x User’s Guide
System Configuration: TID to Modem Mux Configuration
4-31
AI296 Local Menu Item Configuration
1. Access the TID to Modem Mux Menu located under the System Menu.
2. From the System Menu, select
TID to Modem Mux. The TID to Modem Mux
Summary Menu appears.
3. From the TID to Modem Mux Summary Menu, select
[Add TID]. The TID To
Modem Mux Edit Menu appears.
4. For
Port Data Bits, select 7 or 8. The default is 8.
5. For
Port Stop Bits, select 1 or 2. The default is 1.
6. For
Port Parity, select None, Even, or Odd. The default is None.
This example displays:
z Port Data Bits set to 7
z Port Stop Bits set to 1
z Port Parity set to Even.
TID to Route
Description
This menu item defines the string that represents the TID to be routed to the Modem
Mux link.
Menu Item Type
Data
Configuration in the AI198 Menu System
1. Access Menu 4.2.14-2.6.
2. From Menu 4.2.14-2.6, enter a value from
2 to 11. Menu 4.2.14-2.6.1 appears.
3. For
01 TID to route, enter 1, and the desired TID. Maximum length is 20
characters.
This example displays the TID configured as
COLUMBUS-OH.
TID To Modem Mux Edit Menu
TID to route . . . . . . . . . . . . . . . . . . . . .....................
Port Data Bits . . . . . . . . . . . . . . . . . . . . [Seven] Eight
Port Stop Bits . . . . . . . . . . . . . . . . . . . . . . [One] Two
Port Parity . . . . . . . . . . . . . . . . . . . None [Even] Odd
>1 columbus-oh
Menu 4.2.14-2.6.1
01 TID to route-------------------------------------------- COLUMBUS-OH