AI296 Version 9.8x User’s Guide
Link Configuration: General Link Properties Configuration
6-37
Menu 4.2.11.12.5 appears.
Note: 10 Auto Baud is not available for AsyncPPP.
3. Enter a value from
1 to 10 to select the port speed. Menu 4.2.11.12 reappears with
the new port speed selection.
This example displays
05+Port speed set to 4800.
To configure the port speed on an HDLC-Bridge, MLT, SyncPPP, or X.25 link:
1. Access Menu 4.2.11.12.
2. For
Port speed, enter the associated item number, a comma, and the port speed
value.
This example displays
06 Port speed set to 19200.
>5
Menu 4.2.11.12.5
01 300 Baud
02 1200 Baud
03 2400 Baud
04 4800 Baud
05 9600 Baud
06 19200 Baud
07 38400 Baud
08 57600 Baud
09 115200 Baud
10 Auto Baud
>4
Menu 4.2.11.12
01 Link Number (1-16)--------------------------------------------------------01
02*Link Type (Async, X25, HDLC, SyncPPP, AsyncPPP, MLT)---------------- Async
03 Link Description------------------------------ Async link 1
04*Link state (Enabled, Disabled)-------------------------------------- Enabled
05+Port speed------------------------------------------------------------- 4800
>6,19200
Menu 4.2.11.12
01 Link number (1-16)--------------------------------------------------------13
02*Link Type (Async, X25, HDLC, SyncPPP, AsyncPPP, MLT)---------------- HDLC
03 Link Description------------------------------
04*Link state (Enabled, Disabled)--------------------------------------Disabled
06 Port speed (0 - 128000 bps, 0 is external clocking)-------------------019200