Kentrox AI296 Computer Hardware User Manual


 
AI296 Version 9.8x User’s Guide
Link Configuration: Connect Options Configuration
6-14
Connection Settings
Description
The connection settings are configured using three menu items:
z Connect when DCD is on—Enables or disables link connection when DCD is
asserted. If
Connect when characters are received is also enabled and is satisfied
first, then
Connect when DCD is on has no effect on the link connection.
z Connect when characters are received—Enables or disables the link connection
when incoming characters are received. If
Connect when DCD is on is also enabled
and is satisfied first, then
Connect when characters are received has no effect on the
link connection.
z Connect without DSR, DCD or received characters—When this menu item is enabled,
Connect when DCD is on and Connect when characters are received are forced off and
the retry interval is set to
30. If the link application type is set to LOGIN or ALIAS,
connection will occur as soon as the link is enabled (completely independent from
the DCD and incoming character status). If the link application type is set to
DESTINATION, the link will connect immediately when an outgoing call is placed to
the destination (also completely independent from DCD and incoming character
status).
Note: Dial/Connect when DSR is on has no effect on AI296 operation.
Menu Item Type
Toggle
Link Type Availability
Async
Configuration in the AI198 Menu System
1. Access Menu 4.2.11.12.11.
2. For
05*Connect when DCD is on, enter 5 to select ON or OFF. The default is OFF.
3. For
06*Connect when characters are received, enter 6 to select ON or OFF. The default
is
ON.
4. For
07*Connect without DSR, DCD or received characters, enter 7 to select ON or OFF.
The default is
OFF.