Kentrox AI296 Computer Hardware User Manual


 
AI296 Version 9.8x User’s Guide
Link Configuration: X.25 Parameters Configuration
6-82
Menu Item Type
Data
Link Type Availability
X.25
Configuration in the AI198 Menu System
1. Access Menu 4.2.11.12.8.
2. For
05 T20 restart timer, enter 5, and the timer value. The default is 180000.
3. For
06 T21 call timer, enter 6, and the timer value. The default is 200000.
4. For
07 T22 reset timer, enter 7, and the timer value. The default is 10000.
5. For
08 T23 clear timer, enter 8, and the timer value. The default is 180000.
6. For
09 T24 window timer, enter 9, and the timer value. The default is 75000.
7. For
10 T25 data retransmission timer, enter 10, and the timer value. The default is
150000.
8. For
11 T26 interrupt timer, enter 11, and the timer value. The default is 180000.
9. For
12 T28 registration timer, enter 12, and the timer value. The default is 180000.
This example displays:
z 05 T20 restart timer set to 1750000
z 06 T21 call timer set to 1000000
z 07 T22 reset timer set to 20000
z 08 T23 clear timer set to 180000
z 09 T24 window timer set to 2356000
z 10 T25 data retransmission timer set to 1650000
z 11 T26 interrupt timer set to 2300000
z 12 T28 registration timer set to 90000.
>12,90000
Menu 4.2.11.12.8
01*X25 Facilities negotiation-----------------------------------------------OFF
02*Max packet size (128, 256, 512)------------------------------------------128
03 Packet window size (1-7)-------------------------------------------------002
04 X121 local address (0-15 decimal digits)------------------------------------
05 T20 restart timer (0-3200000ms)--------------------------------------1750000
06 T21 call timer (0-3200000ms)-----------------------------------------1000000
07 T22 reset timer (0-3200000ms)----------------------------------------0020000
08 T23 clear timer (0-3200000ms)----------------------------------------0180000
09 T24 window timer (0-3200000ms)---------------------------------------2356000
10 T25 data retransmission timer (0-3200000ms)--------------------------1650000
11 T26 interrupt timer (0-3200000ms)------------------------------------2300000
12 T28 registration timer (0-3200000ms)---------------------------------0090000