AI296 Version 9.8x User’s Guide
Link Configuration: Virtual Circuit Configuration
6-88
2. Enter a value (02 through 15) associated with the PVC to be configured. Menu
4.2.11.12.9.2.1 (the PVC Edit Menu) appears.
3. For
01*PVC Type, enter 1 to select Passive, Active, or Connect on activity. The default
is
Passive.
4. For
02 LCN Low, enter 2, and the minimum LCN value. Valid values are 1 to 1024.
The default is
1.
Note: An asterisk (*) configures all LCNs for the link with values defined in menu
item 4.2.1114.12.9.1.
5. For
03 LCN High, enter 3, and the maximum LCN value. Valid values are 1 to 1024.
The default is
1.
6. For
04 RESET Timer Interval, enter 4, and the reset timer interval value.
The timer type, range, and default settings depend on the PVC type. Refer to
Table 6-1
for PVC types, timer types, ranges, and defaults.
>3
Menu 4.2.11.12.9.2.1
01*PVC Type (Passive, Active, Connect on activity)----------------------Passive
02 LCN Low (* for all LCNs for the link)-----------------------------------0001
03 LCN High----------------------------------------------------------------0001
04 RESET Timer Interval (seconds)-----------------------------------------00000
20 Save the changes made
21 Exit this menu with no changes
Enter item number and optional ",value" then push <CR> key
>
Table 6-1 PVC and Timer Type
PVC Type Timer Type Range Default
Active Call Timer 30 to 600 s 30 s
Connect on Activity Inactivity Timer 1 to 600 s 1 s