Kentrox AI296 Computer Hardware User Manual


 
AI296 Version 9.8x User’s Guide
System Configuration: General System Properties Configuration
4-8
Passive Link Settings
Description
The passive link settings are configured using three menu items. The configurable
values are:
z Passive link down state—Configures standby (DMlock) mode for a passive link.
When this feature is turned on, a passive link will go into DMlock mode after all
calls have cleared. When turned off, a passive link will stay up when all calls have
cleared.
z Passive link stay inactive timer—Sets the number of seconds a passive link waits
for a connection to come up before failing.
z Passive link standby mode timer—Configures the amount of time a link remains in
standby mode before it becomes idle. Immediately after a passive link becomes
inactive, it goes into the standby (DMlock) mode.
Menu Item Types
Toggle for the passive link down state
Data for the passive link stay inactive timer and the passive link standby mode timer
Configuration in the AI198 Menu System
1. Access Menu 4.2.11.
2. For
09*Bring passive link down when all calls have cleared, enter 9 to select ON or
OFF. The default is OFF.
3. For
10 Passive link Stay Inactive timer, enter 10, and a value in seconds for the
passive link stay inactive timer. The minimum value is
25 seconds and the default
is
60 seconds.
4. For
11 Passive link Standby Mode timer, enter 11, and a value in seconds for the
passive link standby mode timer. The minimum value is
5 seconds and the default
is
25 seconds.