AI296 Version 9.8x User’s Guide
Link Configuration: General Link Properties Configuration
6-23
General Link Properties Configuration
General link properties are configurable using menus accessed directly from the link
configuration menu. The following configuration items are available:
Auto Disable Error Limit
Description
This menu item disables a link when the rate of errors received on that link exceeds a
user-specified threshold. This prevents a bad link or cable from streaming enough
errors to lock up or crash AI296.
Menu Item Type
Data
Link Type Availability
Async, AsyncPPP, HDLC-Bridge, MLT, SyncPPP, and X.25
Configuration in the AI198 Menu System
1. Access Menu 4.2.11.12.
2. For
Auto Disable Error Limit, enter the associated item number, a comma, and the
error limit value. (For example,
9,25000.) The default is 0.
z Auto Disable Error Limit z Link Type
z Flow Control z Passive Link with Clocking
z Hardware Interface (Interface Type) z Port Data Bits
z Interface Mode z Port Parity
z Link Description z Port Speed
z Link Mode z Port Stop Bits
z Link Number z Sync Port Encoding
z Link State z Xon Repeat Interval