Kentrox AI296 Computer Hardware User Manual


 
AI296 Version 9.8x User’s Guide
TID Multiplexing: TID Multiplexing Configuration
7-5
5. For 02+Simple alias translation, enter 2. Menu 8.2 appears with the available
translation options.
6. For
04 SLC routing translation, enter 4. Menu 8 reappears with SLC routing
translation
selected for menu item 2.
7. If you are using single alias translation, for
03 Destination, enter 3, and the IP
address of AI296.
8. For
08 Call data, enter 8, and the parent name.
Note: When creating the parent name, note that you use the parent name to
make the children alias names. For example, if a parent is named
PARENT1, valid child names would be PARENT1.1 and PARENT1.2.
9. For
09 App. string, enter:
TMUX
n
[ TID:
tid_for_AI296
]
10. For 10 Called protocol, enter 10,=""
11. (optional) For 11 Caller's protocol, enter 11, and the caller's protocol.
12. Save your changes.
>2
Menu 8.2
01 Simple alias translation
02 Multiplexed connection
03 Multiplexed only translation
04 SLC routing translation
21 Exit this menu with no changes
Enter item number and optional ",value" then push <CR> key
>
n
Defines the maximum number of children connections. Valid
values are 1 to 128.
tid_for_AI296
Defines the terminal identifier for AI296.