Kentrox AI296 Computer Hardware User Manual


 
AI296 Version 9.8x User’s Guide
Link Configuration: Disconnect Options Configuration
6-21
This example displays Disconnect when DCD is off set to On and Disconnect when a Break
character is received
set to Off for an async link.
Disconnect String
Description
This menu item configures the string the link sends before the link disconnects. The
following character values apply:
z <b> sends a break signal.
z <
n
> represents the decimal value of an ASCII character. Valid values are 0 to 255.
z
text
represents the text value in the string.
z <p
#
> represents a pause control sequence.
#
is the number of tenths of seconds
to pause. Valid values are 1 to 20 (for 0.1 seconds to 2 seconds).
For example, string
<b>login<13><p 10><b> sends:
z A break signal
z The text “login”
z A carriage return
z A one second pause
z Another break signal.
Menu Item Type
Data
Link Type Availability
Async
Configuration in the AI198 Menu System
1. Access Menu 4.2.11.12.12.
2. For
07 Disconnect string, enter 7, and the disconnect string. Maximum length is
80 characters.
Disconnect Options Menu
Link being configured . . . . . . . . . . . . . . . . . . . . . . . . . 4
Disconnect when DCD is off . . . . . . . . . . . . . . . . . . . [On] Off
Disconnect when a Break character is received . . . . . . . . . On [Off]