Kentrox AI296 Computer Hardware User Manual


 
AI296 Version 9.8x User’s Guide
TID Multiplexing: TID Multiplexing Configuration
7-7
7. For Application string, enter:
TMUX
n
[ TID:
tid_for_AI296
]
8. For Called protocol, enter ="".
9. (optional) For
Caller's protocol, enter the caller's protocol.
10. Save your changes.
Configuring the Children Aliases
Configuration in the AI198 Menu System
AI296 supports a maximum of 512 child connections. These connections can be X.25,
asynchronous, or TCP/IP.
To configure the child aliases:
1. Log into AI198.
2. At the prompt, enter
menu to access the Main Menu.
3. For
08+Configure the alias translation table, enter 8. The alias configuration
menu appears.
n
Defines the maximum number of children connections. Valid
values are 1 to 128.
tid_for_AI296
Defines the terminal identifier for AI296.
>8
Menu 8
01 Alias name -****************************************************************
02+Simple alias translation
03 Destination -
04 Called address -
05 This alias is visible in the destination menu-----------------------------NO
06 Link number is (1..16) -
07 Caller's address -
08 Call data -
09 App. string -
10 Called protocol -
11 Caller's protocol -
12 Alternate routing alias -
14+Test macros
15 Show entire alias
16 Show the first entry in the alias translation table
17 Show the previous entry in the alias translation table
18 Show the next entry in the alias translation table
19+Delete the above alias translation entry
20 Save the changes made (20b: to the beginning, 20e: to the end)
21 Exit this menu with no changes
Enter item number and optional ",value" then push <CR> key
>