Kentrox AI296 Computer Hardware User Manual


 
AI296 Version 9.8x User’s Guide
Link Configuration: Disconnect Options Configuration
6-18
Disconnect Options Configuration
Disconnect options configure the parameters that are used when AI296 disconnects.
These options are available for asynchronous and asynchronous PPP links. The
following configuration items are available:
z Disconnect Inactivity Timer Settings
z Disconnect Settings
z Disconnect String
Disconnect Inactivity Timer Settings
Description
The disconnect inactivity timer settings are configured using three menu items:
z Disconnect inactivity timer—Defines an inactivity timer value. This value
establishes a timeout interval after which the link will automatically disconnect if
no data has been sent or received for the specified number of seconds. This value
only applies to incoming calls on links that have a retry interval timer setting of
0
and a link application setting of
LOGIN or ALIAS (AppAlias).
Note: The Disconnect inactivity timer option must be set to a value greater than
0 for the inactivity timer to function.
z Inactivity timer enabled when link receives call—Enables or disables the
disconnect inactivity timer when the link receives a call.
z Inactivity timer resets on incoming characters from destination—When enabled,
incoming characters count as activity on a link (the inactivity timer resets). When
disabled, they do not count (the inactivity timer does not reset).
Menu Item Type
Data for disconnect inactivity timer
Toggle for Inactivity timer enabled when link receives call and Inactivity timer resets
on incoming characters from destination
Link Type Availability
Async
Configuration in the AI198 Menu System
1. Access Menu 4.2.11.12.12.
2. For
04 Disconnect inactivity timer, enter 4, and the timer value. The default is 0.