AI296 Version 9.8x User’s Guide
Link Configuration: General Link Properties Configuration
6-32
This example displays Link state set to Down.
Link Type
Description
This menu item defines the type of link as asynchronous, X.25, HDLC, synchronous
PPP, asynchronous PPP, or MLT. Refer to section AI296 Link Types on page 6-2
for
more information about link types.
Menu Item Type
Toggle
Link Type Availability
Async, AsyncPPP, HDLC-Bridge, MLT, SyncPPP, and X.25
Configuration in the AI198 Menu System
1. Access Menu 4.2.11.12.
2. For
02*Link Type, enter 2 to select Async, X25, HDLC, SyncPPP, AsyncPPP, or MLT. The
default is
Async.
This example displays
02*Link Type set to HDLC.
Configuration in the AI296 Local Menu System
1. Access the Link Menu.
2. For
Link Type, select Async, X25, HDLC, SyncPPP, AsyncPPP, or MLT. The default is Async.
This example displays
Link Type set to HDLC-Bridge.
X.25 Link Menu
Link to configure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Link state . . . . . . . . . . . . . . . . . . . . . . . . . . Up [Down]
>2
Menu 4.2.11.12
01 Link number (1-16)--------------------------------------------------------01
02*Link Type (Async, X25, HDLC, SyncPPP, AsyncPPP, MLT)---------------- HDLC
HDLC-Bridge Link Menu
Link to configure . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Link state . . . . . . . . . . . . . . . . . . . . . . . . . . [Up] Down
Link Type . . Async X.25 [HDLC-Bridge] SyncPPP AsyncPPP MLT