Kentrox AI296 Computer Hardware User Manual


 
AI296 Version 9.8x User’s Guide
Link Configuration: X.25 Parameters Configuration
6-79
Link Type Availability
X.25
Configuration in the AI198 Menu System
1. Access menu 4.2.11.12.8.
2. For
13 R20 restart count, enter 13, and the counter value. The default is 1.
3. For
14 R22 reset transmission count, enter 14, and the counter value. The default
is
1.
4. For
15 R23 clear retransmission count, enter 15, and the counter value. The
default is
1.
5. For
16 R28 registration retransmission count, enter 16, and the counter value. The
default is
1.
This example displays:
z 13 R20 restart count set to 150
z 14 R22 reset transmission count set to 25
z 15 R23 clear retransmission count set to 34
z 16 R28 registration retransmission count set to 52.
Configuration in the AI296 Local Menu System
1. Access the X.25 Link Menu.
2. Select
X.25 Parameters Menu. The X.25 Parameters Menu appears.
3. For
R20 restart count, enter the counter value. The default is 1.
4. For
R22 reset transmission count, enter the counter value. The default is 1.
5. For
R23 clear retransmission count, enter the counter value. The default is 1.
>16,52
Menu 4.2.11.12.8
01*X25 Facilities negotiation-----------------------------------------------OFF
02*Max packet size (128, 256, 512)------------------------------------------128
03 Packet window size (1-7)-------------------------------------------------002
04 X121 local address (0-15 decimal digits)------------------------------------
05 T20 restart timer (0-3200000ms)--------------------------------------1750000
06 T21 call timer (0-3200000ms)-----------------------------------------1000000
07 T22 reset timer (0-3200000ms)----------------------------------------0020000
08 T23 clear timer (0-3200000ms)----------------------------------------0180000
09 T24 window timer (0-3200000ms)---------------------------------------2356000
10 T25 data retransmission timer (0-3200000ms)--------------------------1650000
11 T26 interrupt timer (0-3200000ms)------------------------------------2300000
12 T28 registration timer (0-3200000ms)---------------------------------0090000
13 R20 restart count (0 - 255)----------------------------------------------150
14 R22 reset transmission count (0 - 255)-----------------------------------025
15 R23 clear retransmission count (0 - 255)--------------------------------034
16 R28 registration retransmission count (0 - 255)--------------------------052