The Lemur User Manual
99
Channel: Dial in the MIDI channel. If the value is a vector the second field will be extrapolated
automatically. Possible values range from 0 to 16.
6.1.1.8.
F0 – System Exclusive
Used for custom data that is not covered by normal MIDI messages. The first part is
usually a 7 bit value representing an ID. If the device or software recognizes the ID as its own, it
will listen to the rest of the message. Otherwise, the message will be ignored.
trigger: The Variable chosen from the Variable menu that is converted to SysEx messages is
shown here.
data: Type in the desired SysEx string you want to send. Please have a look at the MIDI Target’s
documentation for details about possible SysEx messages.
6.1.1.9.
F2 – Song Position
A 14 bit value that holds the number of MIDI beats (1 beat= six MIDI Timing Tick) since
the start of the song.
position: The Variable chosen from the Variable menu that is converted to song position values is
shown here.
Scale: Type in the desired target scaling for the position pointer. Note that song position pointer
values range from 0 to 16383.
6.1.1.10.
F3 – Song Select
The Song Select specifies which sequence or song is to be played.
song: The Variable chosen from the Variable menu that is converted to song number values is
shown here.
Scale: Type in the desired target scaling for the song number. Possible values range from 0 to
127.
6.1.1.11.
F5 – Bus Select
The Bus Select message specifies to which MIDI output further data should be sent.