4-11
Figure 4-6 Recording Parameter Setup Interface
The table below explains the configuration parameters.
Table 4-12 Conference Recording Configuration
Parameter Description
Enable Recording
If an RSS 2000 is available on your network, you can select
this option to enable the recording function.
Start
Select the start time of the conference recording:
Immediately – The recording automatically starts
immediately after the first participant joins the conference.
Upon Request – The operator or chairperson starts the
recording manually. After this option is selected, the
recording can be manually started through the Web interface
or DTMF function. For more information, see Recording
Control.
Enable Recording
Indication
If this option is selected, the endpoint screen displays the
recording indicator icon to inform participants that the
conference is being recorded:
Note:
Recording indication is not supported in video switching
conference and HD 720p conference.
Terminate
conference if
recording fail …
If this option is selected, the system will terminate the
conference when the recording fails or there is no endpoint in
the lobby.
Audio Only If this option is selected, only the audio will be recorded.
The recording parameters can be set here only after the IP address of the RSS
2000 is configured on the Recording Link interface. For how to set Recording Link,
see Recording Setup.
The Recording Link occupies one conference resource.
If the encryption function is enabled in the Conference Profiles->General
interface, recording will succeed only when the RSS 2000 also supports
encryption.