RoboteQ AX2550 Computer Hardware User Manual


 
AX1500 Motor Controller Users Manual 111
Data Logging in R/C Mode
Output C is a buffered output capable of driving a 2A device at up to 24V. Details on how to
wire this output to user accessories can be found at Connecting Sensors and Actuators to
Input/Outputs on page 51.
The output is activated by pushing the joystick to the maximum position. The output turns
back off when the joystick is returned to the center position.
Note: Channel 3 is not available on the controllers equipped with encoder inputs.
Data Logging in R/C Mode
While in R/C Mode, the AX1500 will continuously send a string of characters on the RS232
output line. This string will contain 12 two-digit hexadecimal numbers representing the fol-
lowing operating parameters.
Captured R/C Command 1 and 2
Power Applied to Controllers output stage
Values applied to Analog inputs 1 and 2
Amps on channel 1 and 2
Internal Heat Sink temperatures 1 and 2
Main Battery voltage
Internal 12V voltage
Encoder Speed or Position feedback, if encoder module is present.
The entire string is repeated every 200 milliseconds with the latest internal parameter val-
ues. This information can be logged using the Roborun Utility (see Viewing and Logging
Data in Analog and R/C Modes on page 176). It may also be stored in a PDA that can be
placed in the mobile robot.
The string and data format is described in Analog and R/C Modes Data Logging String For-
mat on page 156. The serial ports output can be safely ignored if it is not required in the
application.
Output C
ON
Output C
OFF
Output C
OFF
FIGURE 73. Using Channel 3 to activate accessory outputs