RoboteQ AX2550 Computer Hardware User Manual


 
AX1500 Motor Controller Users Manual 133
Accessing & Changing Configuration Parameter in Flash
Reply: None. Controller will reset and display prompt message
Accessing & Changing Configuration Parameter in Flash
It is possible to use RS232 commands to examine and change the controllers parameters
stored in Flash. These commands will appear cryptic and difficult to use for manual param-
eter setting. It is recommended to use the Graphical configuration utility described in
Using the Roborun Configuration Utility on page 161. Note that many parameters will
not take effect until the controller is reset or a special command is sent. The complete list
of parameters accessible using these commands is listed in Automatic Switching from
RS232 to RC Mode on page 155. Reading and writing parameters is done using the fol-
lowing commands:
Read parameter
Syntax: ^mm
Reply: DD
Where mm= parameter number
DD= current parameter value
Example:
^00 Read value parameter 0
01 Controller replies, value is 01
Modify parameter
Syntax: ^mm nn
Reply: + if command was executed successfully
- if error
Where mm= parameter number
nn= new parameter value
Examples:
^02 03 Store 03 into parameter 2
Notes:
All parameters and values are expressed with 2 hexadecimal digits
No changes will be made and an error will be reported (- character) when attempting to
read or write a parameter that does not exist or when attempting to store a parameter with
an invalid value.
Apply Parameter Changes
Description:
Many parameters will take effect only after the controller is reset. This command can be
used (instead of resetting the controller) to cause these parameters to take effect after only
a ~100ms delay.