Operating Modes Registers
Address: ^80 - Channel 1
^81 - Channel 2
Access: Read/Write
Effective: Instantly
Modifying the bits in the Operating Mode registers will change the controllers operating
modes on-the fly. Changes take effect at the controllers next 16ms iteration loop. After
reset, these bits get initialized according to the configuration contained in Flash.
Values are in Hexadecimal.Example: 00000101 = Hex 05
Read/Change PID Values
Address: ^82 - P1
^83 - I1
^84 - D1
^85 - P2
^86 PID Differential gain 1 R/W
^87 PID Differential gain 2 R/W
^88 PWM frequency R/W
^89 Controller Status R Only
^8A Controller Model R Only
^8B Current Amps limit 1 R Only
^8C Current Amps limit 2 R Only
TABLE 24. Operating Modes Register Definition
Bit Function
7 to 3 Not Used
2 0: Open Loop
1: Closed Loop
(when in Speed Mode)
1 0: Speed Mode
1: Position Mode
0 0: Analog Feedback
1: Encoder Feedback
TABLE 23. Runtime R/W Parameters list