Sun Microsystems X2250 Server User Manual


 
Chapter 1 Sun Fire X2250 Server Overview 1-9
1.4.4 Clearing the CMOS
You can use this procedure to clear the server's CMOS settings in the case of a system
hang.
For example, if the server hangs because of incorrect settings and will not boot, use
this procedure to invalidate the settings and reboot with the default settings.
1. Remove the AC power cord.
See
FIGURE 1-2 for the location of the power cord connection.
2. Remove the battery for 30 seconds, then reinsert it.
See Chapter 4 for instructions on removing and replacing the battery.
3. Reinsert the AC power cord.
1.5 Customer-Orderable Components
You can order additional components and replacement parts for the Sun Fire X2250
server.
Contact your local Sun sales representative for more information. For the most
up-to-date component information, see the components list on the following web
site:
http://sunsolve.sun.com/handbook_pub/Systems/