Sun Microsystems X2250 Server User Manual


 
Chapter 4 Maintaining the Sun Fire X2250 Server 4-13
4. Check the routing of all cables for obstructions, and then reinstall the cover as
described in Section 4.3, “Powering Off the Server and Removing the Cover” on
page 4-3.
4.5.3 Replacing a Hard Disk Drive and Carrier
The following procedures describe how to remove and replace a hard disk drive
(HDD) and carrier.
4.5.3.1 Removing an HDD and Carrier
To remove the HDD and carrier:
1. If you are not using an integrated-mirroring (IM) configuration, you must power
off the server before removing an HDD; it is not necessary to remove the cover.
Power off the system as described in Section 4.3, “Powering Off the Server and
Removing the Cover” on page 4-3.
If you are using an IM configuration, start with Step 2.
2. Squeeze the release latch on the HDD and carefully swing the arm to the left as
far as it will go.
FIGURE 4-11 Removing a Hard Disk Drive