Sun Microsystems X2250 Server User Manual


 
4-18 Sun Fire X2250 Server Service Manual April 2009
4.5.5 Removing and Installing the ODD Drive
Assembly
The following procedure describes how to replace the optical disk drive (ODD)
assembly. If you are not replacing a DVD drive, go to Section 4.5.5.2, “Installing the
ODD Drive Assembly” on page 4-19.
4.5.5.1 Removing the ODD Drive Assembly
To remove the ODD (DVD or CD) drive assembly:
1. Power off the system and remove the cover as described in Section 4.3,
“Powering Off the Server and Removing the Cover” on page 4-3.
2. Unfasten the drive ribbon cable from the ODD drive.
Caution Use care with the small flat cables. They are extremely fragile.
FIGURE 4-15 Removing the DVD Drive Assembly
3. Push the latch on the back of the ODD drive toward the drive until the ODD
drive springs forward out of the chassis.