4-18 Sun Fire X2250 Server Service Manual • April 2009
4.5.5 Removing and Installing the ODD Drive
Assembly
The following procedure describes how to replace the optical disk drive (ODD)
assembly. If you are not replacing a DVD drive, go to Section 4.5.5.2, “Installing the
ODD Drive Assembly” on page 4-19.
4.5.5.1 Removing the ODD Drive Assembly
To remove the ODD (DVD or CD) drive assembly:
1. Power off the system and remove the cover as described in Section 4.3,
“Powering Off the Server and Removing the Cover” on page 4-3.
2. Unfasten the drive ribbon cable from the ODD drive.
Caution – Use care with the small flat cables. They are extremely fragile.
FIGURE 4-15 Removing the DVD Drive Assembly
3. Push the latch on the back of the ODD drive toward the drive until the ODD
drive springs forward out of the chassis.