4-14 Sun Fire X2250 Server Service Manual April 2009
3. Grasp the carrier bezel with both hands and carefully pull the carrier out of the
drive bay.
Note Avoid using the arm to remove the carrier.
4. Reinsert the HDD and carrier into the server as described in Section 4.5.3.2,
“Installing an HDD and Carrier” on page 4-14.
4.5.3.2 Installing an HDD and Carrier
Note If you are installing a new HDD, rather than replacing an already installed
HDD, you will need to remove the empty carrier from the drive cage before
installing the new HDD. See instructions for Removing an HDD and carrier.
To install the HDD and carrier:
1. Squeeze the release latch on the HDD and carefully swing the arm to the left as
far as it will go.
FIGURE 4-12 Installing a Hard Disk Drive
2. Grasping the body of the drive in both hands, carefully guide the connector end
of the carrier into the drive bay, sliding the carrier into the bay until the latch
engages and partially closes itself.
3. Push the latch forward until it locks to secure the carrier in place.