Sun Microsystems X2250 Server User Manual


 
Chapter 4 Maintaining the Sun Fire X2250 Server 4-45
TABLE 4-3 describes the motherboard cable connections.
4.5.15 Motherboard
The following procedures describe how to remove and install the Sun Fire X2250
server system motherboard.
Note The motherboard is not a CRU and should be replaced only by trained field
service technicians.
4.5.15.1 Removing the Motherboard
To remove the motherboard:
1. Power off the system and remove the cover as described in Section 4.3,
“Powering Off the Server and Removing the Cover” on page 4-3.
2. Remove the PCIe card riser assembly installed on the motherboard (see
Section 4.5.2, “Replacing the PCIe Card and Riser Assembly” on page 4-9) and the
air duct (see Section 4.5.6, “Replacing the Air Duct” on page 4-20).
3. Disconnect all cables attached to the motherboard.
4. Remove the four screws from the heatsink (4 screws per heatsink installed).
Note Do not remove the screws that secure the CPU heatsink assemblies mounting
to the motherboard.
5. Using a Phillips screwdriver, remove the seven Phillips screws that fasten the
motherboard to the chassis.
TABLE 4-3 Motherboard Cable Connections
Label Label
1 J9C1 - power supply 6 HDD0 and HDD1 - power supply
2 J9E1 - power supply 7 SATA1 - HDD1
3 J2K2 - ODD 8 SATA0 - HDD0
4 JP2 - Blower Module and Fan 0 9 J4K1 - power supply
5 J112 - I/O board