Toshiba e-STUDIO500P Printer User Manual


 
Diagnostic information 2-89
922.xx—Cold fuser check
Error codes 920.xx and 922.xx may display for a cold fuser failure.
Some 920.xx error codes may be cleared by turning the printer on and off and allowing it to complete POR.
CAUTION: There is a danger from hazardous voltage in the area of the printer where you are
working. Unplug the printer before you begin, or use caution if the printer must receive power in
order to perform the task.
Service tip: Set the Fuser Temperature to NORMAL before starting this service check. In Diagnostics mode,
select EP SETUP, and Fuser Temp.
FRU Action
1 Fuser lamp Remove the fuser assembly and check to make sure the correct fuser
lamp has been installed. If the correct lamp has been installed, go to
step 2.
Note: If the fuser lamp is replaced, allow the fuser assembly to cool
or a 925.xx error code could be displayed.
2
AC line voltage CAUTION: When taking measurements for AC power, observe all
safety precautions.
Check the AC line voltage to make sure it is within operating
specification. If incorrect, inform the customer; if correct, go to step 3.
3
LVPS CAUTION: When taking measurements for AC power, observe all
safety precautions.
Unplug the AC line cord from the printer and pull the LVPS out far
enough to access CN1 on the LVPS board (see “Low voltage power
supply removal” on page 4-54). Disconnect the LVPS to fuser AC
cable, plug in the line cord, turn the printer on and measure the
voltage between CN1-1 and CN1-3 on the connector (see the
connector locations at “Low voltage power supply removal” on
page 4-54).
If incorrect, replace the LVPS assembly (see “Low voltage power
supply removal” on page 4-54); if correct, go to step 4.
4
LVPS
LVPS fuser AC cable
CAUTION: When taking measurements for AC power, observe all
safety precautions.
Disconnect the AC line cord from the printer. Disconnect the LVPS to
fuser cable from the fuser to fuser lamp cable. Plug the AC line cord
into the printer and check the AC line voltage between the pins on the
fuser end of the LVPS to fuser AC cable. If the voltage is correct,
unplug the AC power cord from the LVPS cable and pull the LVPS out
far enough to be able to check the voltage between CN-1 and CN-3
on the LVPS board. Plug in the power cord, turn the printer on and
check the voltage. If correct, replace the LVPS to fuser AC cable; if
incorrect, replace the LVPS assembly. See “Low voltage power
supply removal” on page 4-54.
Note: If the fuses in the LVPS are blown, the LVPS assembly must be
replaced.
5
Fuser top cover assembly
(thermistor, thermistor
cable)
Fuser to system board DC
cable
Check to make sure that the thermistor is installed correctly to J5 on
the fuser control card. If installed correctly check the cable for any
signs of damage. If any problems are found, replace the fuser top
cover assembly.“Fuser narrow media sensor removal” on
page 4-34.
If no problem is found, check the fuser to system board DC cable for
correct installation at J1 on the fuser control card. If no problem is
found, check the fuser to system board cable for correct installation at
J10 on the system board. If no problem is found, go to step 6.